Autronic SM4
Overview
The SM4 is our latest model ECU. This ECU has many features which allow it to be setup to suit various types of engine configurations. It has very flexible options over how the inputs and outputs are controlled, and allows the user to design their own functions to control all sorts of devices. Precise control of injectors and ignition angle are guaranteed at very low or highRPM or manifold pressures. A very high level of protection from interference and tolerance of trigger input errors has been built into this ECU, ensuring a smooth running engine even under the most demanding conditions.
Inputs
Triggering:
Compatable with Magnetic and Hall Effect Sensors,or any combination for Camshaft & Crankshaft Sensor Inputs. Response speed is also software configurable for improved noise immunity. Multi tooth, Missing tooth, Subaru, Mitsubishi, Ford TFI and Gen3 triggers. Software selectable trigger angle.
Sensors:
- Autronic or NTC Air Temp Sensors,NTC Coolant Temp,Throttle Position Sensors software selectable.
- Included 4.4 bar Absolute(50 psi boost)Internal or External MAP sensor, software selectable.
- Support for air flow meters.
- Internal Pressure sensor useable for MAP &/or barometric sensing.
Additional Inputs:
- 3 x Spare Analog inputs (EGT, EBP, 02, etc...) Spare Analog Inputs may be used as additional
- Switch Inputs. Analog Inputs can be set for predefined calibrations or user defined calibrations.
- Variable Camshaft control for up to two camshafts. VANOS and other VVT supported.
- Knock control with individual cylinder retard (requires installation or additional internal module).
Outputs
Injection:
- Eight Injector Outputs. Software Selectable 4/1 amp 2/0.5 amp Peak/Hold type for High & Low Current Injector types or parallel operation of injector pairs.
- Rating may be specified independently for 2 groups of 4 O/Ps. Sequential, single or double shot 1 or 2 group fire possible for up to 16 injectors.
- Up to 7 injector outputs are useable for alternate functions.
Ignition:
- Four ignition Outputs, up to Eight with external Ignition Multiplexer.
- Rating Push-Pull +/-1 amp max.
- Software selectable Dwell (Inductive) or Pulse (CDI) Output.
- Dwell Time mappable vs. Rpm,Load,and Voltage.
- Up to 3 useable for alternate functions.
Software
Mapping via Manifold Pressure, Throttle Position, Manifold and Throttle or Manifold, Throttle and Exhaust Backpressure Fuel and Ignition tables have up to 32 rpm and 16 load site axis, user selectable. Air/Fuel Ratio Table, allows user to input air/fuel ratio vs. load and RPM, to be used with Autotune,Manual Tune,Mixture Table,Closed Loop Control, and also for quick easy changes to engine Air/Fuel Ratio anytime, without an O2 input needed, after the engine is initially tuned. "Autotune" Feature allows user adjustable (within 1-5%) fuel base map tuning in real time, hands free operation when used with Autronic Air/Fuel Analyzer. Fuel map will color each cell tuned to specified accuracy and lock the values to prevent accidental changing. Best used during steady state tuning on engine or chassis dyno. "Manual Tune" Feature allows the fuel map to be tuned using the datalog, each cell on the map individually tuned to the air/fuel ratio specified in the Air/Fuel Ratio Table. "Mixture Table" Feature records the air/fuel ratio and number of times recorded at each fuel table cell, allowing the user to calibrate these cells to the air/fuel ratio specified in the Air/Fuel Ratio Table with a single keystroke. 13 General purpose control modules for O/P control.(use for variable fuel pump, power steering, inlet manifold air valves, extra temperature control devices etc) 4 of these are capable of PID feedback control (typical application for PIDs are variable camshaft positioning or inlet manifold length).Datalogging
Up to 50X per second Sampling Rate. Fully User Selectable Graphing, set up number of channels displayed,min and max values,color,etc. Overlay multiple graphs to compare data. Display datalog and tuning maps on the same screen,tuning maps have display "tracer" to indicate corresponding area of datalog for easy and quick changes to map.
| Microcomputer |
.
|
Intel 16 bit running @ 20Mhz |
| Supply Voltage |
Normal operation
Safe limits |
6.2V
to 23V DC continuous +/- 24V (5 min) +/- 80V alternator load dump (0.5 sec). +/- 1000V inductive spike (10 usec) |
| Current Drain |
@ Engine idle
@ Max Engine Load |
<
1 Amp. < 16 Amp (less depending on injector type and number. |
| Operating Temperature
Range |
Min
Max |
- 40
deg C. + 85 deg C. |
| Engine Cylinder Number Settings |
Number of cylinders
|
1, 2, 3, 4, 5, 6, 7, 8, 10, 12, 14 and 16 |
| Engine RPM Range |
0 to 30,000 RPM
0 to 16,000 RPM 0 to 15,000 RPM |
Engines
up to 4 cylinders Engines up to 5 to 8 cylinders. Engines 10 to 16 cylinders. |
| Injection Duration Timing |
Min
Max Accuracy Settingresolution |
0.65
msec. 50 msec. +/- < (10 usec + 1%) 0.1% approx. |
| Injection Timing |
Range
Accuracy Settingresolution |
0
to 720 deg (crank angle). +/- < (1.4 deg + 0.3 msec). 2.8 deg. |
| Ignition Timing |
Advance range
Accuracy Settingresolution |
0
to 45 deg (crank angle). +/- 0.2 deg (crank angle). 0.5 deg (crank angle). |
| Fuel Delivery and Ignition Mapping |
No. Load sites
No. RPM sites |
16
(max). Both
Load and RPM sites 32 (max). are freely selectable. |
| Data Logging Memory |
Size
|
112k |
| Size |
L * W * H
|
130 * 124 * 48mm |
| Weight | . | 0.5 kg |
| Connectors |
.
|
42 way 'AMP' water and dust proof socket |